Price 700000.00 INR/ Piece
Column and Heat Exchanger Specification
- Temperature
- -20C to 300C
- Max. Capacity
- Up to 50,000 L/hr
- Diameter
- 300 mm to 2400 mm
- Number of Pipe
- Multiple; Usually 25 - 100 tubes
- Thickness
- 8 mm to 20 mm
- Max Pressure
- 25 bar
- Condition
- New
- Structure
- Vertical Cylindrical Column with Integrated Heat Exchanger
- Liquid Flow Rate
- 1500-25000 L/hour
- Working Presssure
- Up to 25 bar
- Voltage
- 220V / 380V / 415V
- Power
- Electric, as per custom requirements
- Weight
- Depends on model; usually 500 - 2000 kg
- Dimensions
- Custom as per design; Approx. 1000 mm diameter x 4000 mm height
- Design Standard
- ASME, IS, DIN, as required
- Tube Type
- Seamless/ERW tubes
- Corrosion Resistance
- Excellent with SS 316
- Surface Finish
- Polished or as per customer requirement
- Color
- Metallic Silver or as required
- Mounting Type
- Vertical Floor Mounted
- Leak Test
- Hydrostatic and Pneumatic tests
- Connection Type
- Flanged/Threaded/Socket Welded
- Insulation
- Mineral wool/PUF available for shell
- Application
- Distillation, Absorption, Chemical Processing
- Gasket Type
- PTFE/Fiber/Spiral Wound
- Material of Construction
- Stainless Steel 304/316, Carbon Steel Available
- Heat Transfer Area
- Up to 150 m² (customized)
Column and Heat Exchanger Trade Information
- Minimum Order Quantity
- 1 Piece
- Payment Terms
- Cash Advance (CA), Cheque
- Supply Ability
- Piece
- Delivery Time
- Week
- Main Domestic Market
- All India
About Column and Heat Exchanger
The column and a heat exchanger are the different types of equipment suited to be used in chemical as well as process industries. One of which is a vertical vessel, which can separate the mixture of liquids at different boiling points. On the other hand, another unit is the device, which can transfer heat between two fluids, typically a cold fluid and a hot fluid. Column and a heat exchanger is highly essential equipment demanded in many industries for several purposes. The said units are suited for the effective separation as well as purification of liquid mixtures.
Superior Materials for Maximum Corrosion Resistance
Our heat exchangers and columns are fabricated using premium Stainless Steel 304 or 316, as well as Carbon Steel, to offer outstanding mechanical strength and resistance to chemical corrosion. When SS 316 is selected, the unit achieves excellent corrosion protection, making it ideal for processing harsh chemicals or demanding operating environments.
Flexible Design and Customization Options
With customizable heat transfer areas (up to 150 m), surface finishes, insulation types, and connection configurations, our systems are tailored to meet precise process requirements. Whether you need a specific dimension, operating pressure up to 25 bar, or specialized mounting, we deliver solutions that align perfectly with your application needs.
Reliable Performance and Stringent Testing
Each unit undergoes hydrostatic and pneumatic leak tests to ensure system integrity prior to dispatch. Built to international design codes (ASME, IS, DIN), and capable of handling voltages from 220V to 415V, our columns and heat exchangers guarantee robust and secure operation across a wide spectrum of industrial scenarios.
FAQs of Column and Heat Exchanger:
Q: How do I choose the right material of construction for my heat exchanger or column?
A: Selection depends on your process fluid and operating environment. Stainless Steel 316 offers excellent corrosion resistance, making it suitable for aggressive chemicals, while Stainless Steel 304 and Carbon Steel are ideal for less corrosive applications. Our team can advise the best material choice based on your requirements.Q: What is the typical process for installation and commissioning of the vertical floor-mounted columns?
A: After delivery, our technical team can guide you through the installation, which includes vertical floor mounting, connection integration (flanged, threaded or socket welded), insulation application, and system testing via hydrostatic or pneumatic methods, ensuring your system is safely commissioned.Q: When should mineral wool or PUF insulation be used on the heat exchanger shell?
A: Insulation is recommended when there is a need to minimize heat loss or protect operators from high surface temperatures. Mineral wool or PUF can be selected based on your process temperature and safety requirements; our experts can assist in determining the optimal insulation for your application.Q: Where are these columns and heat exchangers commonly used?
A: Our products are widely utilized in industries such as chemical processing, refineries, pharmaceuticals, and petrochemicals where distillation, absorption, or precise temperature control is necessary. They are suitable for both new projects and retrofit upgrades.Q: What are the main benefits of using seamless/ERW tubes in the heat exchanger?
A: Seamless or ERW tubes offer enhanced durability, uniform heat transfer, and lower risk of leakage, ensuring long-term, efficient performance. The choice depends on pressure requirements and process compatibility, and both types support high operational reliability.Q: How does the leak testing process work for these units?
A: All columns and heat exchangers undergo rigorous hydrostatic and pneumatic leak testing to certify their integrity. These tests involve pressurizing the system above normal operating pressure with water or air, inspecting for leaks to ensure safe and reliable performance before use.Q: What customization options are available for dimensions, capacity, and design standards?
A: We offer a range of customizable options including column diameter (300 mm to 2400 mm), height, heat transfer area, number of tubes, working pressure (up to 25 bar), and compliance with ASME, IS, or DIN standards. Designs can be tailored to meet specific process and regulatory requirements.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Heat Exchangers Category
Heat Exchanger
Minimum Order Quantity : 1 Square Meter
Structure : Other, Shell and Tube
Condition : New
Heat Exchanger Tube Plate
Price 86000 INR / Piece
Minimum Order Quantity : 1 , , Piece
Structure : tube Heat Exchanger
Condition : New
Color : Gray
Product Type : Heat Exchanger Tube Plate
Heat Exchanger and FFR
Price 350000.00 INR / Piece
Minimum Order Quantity : 1 Piece
Structure : Other, Tubular
Condition : New
Color : As Per Requirement
Product Type : SemiAutomatic
![]() |
HARDCORE ENGINEERS
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |